SKU: 013.001.0072
MeanWellPB-1000-12
Lead-acid battery charger 14.4V/60A
To see purchase prices you must be a registered user!
Indicative retail price (incl. 24% VAT): 403,31 €
Lead battery charger 12V / 60A, Charging selection on 2 stages (one charge), on 3 stages (charging and load power) or 8 stages (maintenance charging and permanent connection to the battery).
Package weight: 0,400kg
Package volumetric: 0,500kg
Package weight: 0,400kg
Package volumetric: 0,500kg
Output
Boostcharge voltage14.4V
Floatcharge Voltage13.8V
Output Current60A
Recommended battery capacity (Amp Hours) (Note 3)200 ~ 600Ah
BatterytypeOpen & Sealed Lead Acid
Leakage current from battery<1mA
Input
Voltage range90 ~ 264V AC / 127 ~ 370V DC
Frequency range47 ~ 63Hz
Powerfactor (typ.)0.95/230V AC 0.98/115V AC at full load
Efficiency (typ.)85%
Ac Current (typ.)12A/115V AC 5.2A/230V AC
Inrushcurrent (typ.)25A/115V AC 50A/230V AC
Leakage current<3.5mA / 240V AC
Protection
Overvoltage16~18V
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
Overtemperature80° C ±5° C (12V), 85° C ±5° C (24V,48V) (TSW1: detect on heatsink of power transistor)
85° C ±5° C (12V), 75° C ±5° C (24V,48V) (TSW2 : detect on heatsink of o/p diode)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
85° C ±5° C (12V), 75° C ±5° C (24V,48V) (TSW2 : detect on heatsink of o/p diode)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
Short CircuitYES, protected by internal circuit
Reverse PolarityYES, protected by internal circuit
Function
Remote ControlOpen: Normal work Short: Stop Charging
Batterbanks2 banks (A & B)
Fastcharge2 / 3 / 8 stage selectable
Charger OkRelay contact rating(max.): 30V/1A resistive ; "Short" when the unit is working properly, "Open"when the unit is failure or the protection function is activating
Output OkRelay contact rating(max.): 30V/1A resistive ; "Short" when the battery is full, "Open" when the battery is still charging
Temperature CompensationBy NTC, compensate both banks at the same time
Environment
Workingtemp.-20 ~ +60° C (Refer to "Derating Curve")
Workinghumidity20 ~ 90% RH non-condensing
Storage Temp., Humidity-40 ~ +85° C, 10 ~ 95% RH
Temp. Coefficient±0.05%/° C(0~50° C)
Vibration10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Safety & EMC (Note 2)
SafetystandardsUL60950-1, TUV EN60950-1 approved
Withstand VoltageI/P-O/P:3KV AC I/P-FG:2KV AC O/P-FG:0.5KV AC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500V DC/ 25° C/ 70% RH
EmcemissionCompliance to EN55022 (CISPR22), EN61000-3-2,-3
EmcimmunityCompliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
Others
MTBF127.4K hrs min. MIL-HDBK-217F (25° C)
Dimension300*184*70mm (L*W*H)
Weight3.5Kg